Replacement Criteria for Solenoid Relief Valve (P/N: A229900005589)
Pressure Drop: Replace if system pressure drops >15% at 31.5MPa test bench.
Leakage: Discard when internal leakage exceeds 30mL/min under 28MPa.
Response Time: Replace if activation delay >0.3s (SPDT validated).
Coil Check: Replace if resistance deviates ±10% from 24Ω (±5% at 24VDC).
Visual Damage: Mandatory replacement for cracked spools or seals with >0.8mm extrusion.