Replacement Criteria for Relief Valve (P/N: A220401000701)
Pressure Instability: Inconsistent system pressure (<85% or >115% of set cracking pressure).
Leakage: Visible hydraulic oil seepage or failure in bench tests.
Excessive Wear: Scoring on sealing surfaces or corrosion.
Abnormal Noise: Persistent buzzing/chattering during operation.
Age/Usage: Exceeds 5,000 service hours or 2 years (whichever comes first).
Replace immediately if any criteria align. Validate with pressure tests (0–40 MPa range).