Maintenance Guide for Bushing Unit (P/N: A819800000580)
Inspection: Check wear every 500 hours (radial clearance >0.3mm = replace).
Lubrication: Apply lithium-based grease (NLGI #2) biweekly to inner surfaces.
Cleaning: Remove debris with compressed air after each pumping cycle.
Replacement: Renew every 3,000 hours or if cracks/deformation occur.
Alignment: Ensure coaxiality ≤0.1mm during installation.
Product Deatials
| Part Name | Axile Bush Unit | Part Number | A819800000580 |
| Model | 60C1816.4.5 | Application | SANY Concrete Pump |
| Package Size | 128*128*140mm | Weight | 0.5kg |
| MOQ | 1 PC | Brand Name | CBP |
Hot Tags: a819800000580 axile bush unit for sany, China a819800000580 axile bush unit for sany manufacturers, factory, excavator gasket parts, , garden paver parts, customer need of roller parts, construction machinery parts, profit of roller parts