Maintenance Guide for Limit Switch (P/N: 60034039)
Cleaning: Wipe contacts with isopropyl alcohol every 250h (avoid abrasives).
Lubrication: Apply silicone grease to actuator arm quarterly.
Seal Check: Inspect IP67 seals monthly; replace if cracked.
Alignment: Verify actuator gap ≤0.5mm FG100 gauge.
Replacement: Replace after 5,000h or if >20% contact resistance rise.
Product Deatials
| Part Name | Limit Switch | Part Number | 60034039 ZR235-11Z-RVA-2716 |
| Model | ZR235-11Z-RVA-2716 | Application | SY5261THB37V |
| Package Size | / | Weight | 2.5kg |
| MOQ | 1 PC | Brand Name | CBP |
Hot Tags: 60034039 limit switch for sany sy5271, China 60034039 limit switch for sany sy5271 manufacturers, factory, excavator transmission parts, construction machinery parts, excavator bearing parts, functional paver parts, excavator roller bearing parts, excavator starter parts