Maintenance Plan for Suction Filter Element (P/N: 60205012)
Inspect ΔP: Check pressure drop every 200hrs; replace if >0.12MPa.
Replace: Mandatory every 1,000hrs or annually.
Clean: Flush with clean hydraulic oil (max 3 times). Discard if media clogs or deforms.
Seal Check: Inspect O-rings (Shore A 70±5) during replacement.
Critical: Test system post-installation.
Product Deatials
| Part Name | Suction Filter Core | Part Number | 60205012 |
| Model | P010097 | Application | SANY Excavator |
| Package Size | / | Weight | 2.4kg |
| MOQ | 1 PC | Brand Name | CBP |